O940728M |
Cefoxitin sodium |
Antibiotics |
Caffeine
Cefoxitin sodium |
J'sphere ODS-H80 |
JH08S04-L546WT |
O940728P |
Cefoxitin sodium |
Antibiotics |
Caffeine
Cefoxitin sodium |
J'sphere ODS-H80 |
JH08S04-L502WT |
O940729A |
Cefoxitin sodium |
Antibiotics |
Caffeine
Cefoxitin sodium |
J'sphere ODS-H80 |
JH08S04-1502WT |
O950908A |
Penicillin antibiotics |
Antibiotics |
Bacampicillin hydrocloride
Methicillin sodium
Penicillin G potassium (Benzylpenicillin potassium)
Penicillin V potassium (Phenoxymethylpenicillin potassium)
Phenethicillin potassium (Phenoxyethylpenicillin potassium)
Cloxacillin sodium
Propicillin potassium
Dicloxacillin sodium |
J'sphere ODS-H80 |
JH08S04-1546WT |
O950920C |
Penicillin antibiotics |
Antibiotics |
Amoxicillin hydrate
Ampicillin anhydrous |
J'sphere ODS-H80 |
JH08S04-L546WT |
S000622D |
Amoxicillin |
Antibiotics |
Amoxicillin
Caffeine |
Hydrosphere C18 |
HS12S05-1546WT |
F100329A |
Erythromycin antibiotic drugs |
Antibiotics |
Erythromycin
Erythromycin ethylsuccinate
Erythromycin estolate |
YMC-Triart C18 |
TA12S03-0502WT |
S930910B |
Erythromycin antibiotic drugs |
Antibiotics |
Erythromycin
Erythromycin ethylsuccinate
Erythromycin estolate |
J'sphere ODS-H80 |
JH08S04-1546WT |
F100416A |
Clindamycin hydrochloride (The United States Pharmacopoeia) |
Antibiotics |
Lincomycin hydrochloride
Clindamycin hydrochloride |
YMC-Triart C18 |
TA12S05-2546WT |
F100416B |
Clindamycin hydrochloride (The Japanese Pharmacopoeia 15th Edition SupplementⅡ) |
Antibiotics |
Clindamycin hydrochloride |
YMC-Triart C18 |
TA12S05-2546WT |
F100128B |
LC/MS analysis of tetracycline antibiotics |
Antibiotics |
Oxytetracycline
Tetracycline
Chlortetracycline
Doxycycline |
YMC-Triart C18 |
TA12S05-0502WT |
S970524D |
Tetracycline antibiotics |
Antibiotics |
Oxytetracycline hydrochloride
Tetracycline hydrochloride |
YMC-Pack Pro C18 |
AS12S05-1546WT |
S000728B |
Vancomycin |
Antibiotics |
Vancomycin hydrochloride
4'-Hydroxyacetophenone |
Hydrosphere C18 |
HS12S05-1546WT |
S080702B |
Simultaneous separation of pesticides by LC/MS - fast LC |
Pesticides, Environmental |
Thiamethoxam Clothianidin
Chloridazon Thiacloprid
Thiabendazole Azamethiphos
Dimethirimol Isoxaflutole
Pyriftalid (E)-Ferimzone
(Z)-Ferimzone Methoxyfenozide
Iprovalicarb Chromafenozide
Butafenacil Simeconazole
Cyazofamid Naproanilide
Fenoxycarb Anilofos
Cyflufenamid Pyrazolynate
Indoxacarb Benzofenap
Furathiocarb Cloquintocet-mexyl |
YMC-UltraHT Pro C18 |
AS12S02-L502WT |
S080702A |
Simultaneous separation of pesticides by LC/MS |
Pesticides, Environmental |
Thiamethoxam Clothianidin
Chloridazon Thiacloprid
Thiabendazole Azamethiphos
Dimethirimol Isoxaflutole
Pyriftalid (E)-Ferimzone
(Z)-Ferimzone Methoxyfenozide
Iprovalicarb Chromafenozide
Butafenacil Simeconazole
Cyazofamid Naproanilide
Fenoxycarb Anilofos
Cyflufenamid Pyrazolynate
Indoxacarb Benzofenap
Furathiocarb Cloquintocet-mexyl |
YMC-Pack Pro C18 |
AS12S03-1502WT |
U110127A |
Pesticides used on golf course - method transfer from HPLC to UHPLC |
Pesticides, Environmental |
Oxine-copper
(Copper 8-quinolinolate)
Asulam
Thiram
Triclopyr
Mecoprop
Flazasulfuron
Siduron
Halosulfuron-methyl
Azoxystrobin |
YMC-Triart C18 |
TA12SP9-0502PT |
U110127A |
Pesticides used on golf course - method transfer from HPLC to UHPLC |
Pesticides, Environmental |
Oxine-copper
(Copper 8-quinolinolate)
Asulam
Thiram
Triclopyr
Mecoprop
Flazasulfuron
Siduron
Halosulfuron-methyl
Azoxystrobin |
YMC-Triart C18 |
TA12S05-1502WT |
F100326C |
Rapid analysis of pesticides used on golf course |
Pesticides, Environmental |
Oxine-copper
(Copper 8-quinolinolate)
Asulam
Triclopyr
Thiram
Mecoprop
Flazasulfuron
Siduron
Halosulfuron-methyl
Azoxystrobin |
YMC-UltraHT Hydrosphere C18 |
HS12S02-1003WT |
N040107A |
Analysis of 9 pesticides |
Pesticides, Environmental |
Oxine-copper (Copper 8-quinolinolate)
Carbendazim (MBC)
Asulam
Thiophanate-methyl
Thiram
Mecoprop (MCPP)
Siduron
Iprodion
Bensulide (SAP) |
Hydrosphere C18 |
HS12S05-1546WT |
A010717A |
Copper 8-quinolinolate |
Pesticides, Environmental |
Copper 8-quinolinolate |
Hydrosphere C18 |
HS12S05-1502WT |